Low-voltage power cable
Description
1. Product features and uses
This product is suitable for transmission lines in automatic control or monitoring systems, electrical instrument connection, etc., with a rated voltage of AC 450/750V and below.
Low-smoke halogen-free polyolefins have low smoke generation and no halogen acid gas release during combustion, belonging to environmental-friendly cables, suitable for occasions with special fire protection requirements.
Two: Product Implementation Standard
GB9330-88
Flame retardant performance test is carried out according to GB12666-90 standard
Three: Using Properties
1. Rated voltage for AC: U0/U 450/750KV
2. Maximum operating temperature: PVC (PE) insulation not to exceed 70℃
Cross-linked polyethylene insulation 90℃
Low-smoke, halogen-free, flame retardant polyolefin 70℃
Low-smoke, halogen-free, flame retardant cross-linked polyolefins at 90℃ and 125℃
3. Minimum ambient temperature: PVC sheath: fixed laying -40℃, non-fixed laying -15℃
4. The temperature for cable installation and laying should not be lower than 0℃.
5. Allowable bending radius of cables: minimum 6 times the outer diameter of the cable for non-armored cables
Copper tape shielding or steel tape armoring cable minimum is 12 times the cable outside diameter
Four: Basic Model and Name
1. PVC insulated and sheathed control cables
|
KVV |
Control cable with copper core, PVC insulation and PVC sheath |
|
KVVP |
Control cable with copper core, PVC insulation, PVC sheath, and copper wire braid shielding. |
|
KVVP2 |
Control cable with copper core, PVC insulation, PVC sheath, and copper tape shielding. |
|
KVV22 |
Control cable with copper core, PVC insulation, PVC sheath, steel tape armor. |
|
KVVR |
Control flexible cable with copper core, PVC insulation and PVC sheath |
|
KVVRP |
Control soft cable with copper core, PVC insulation, PVC sheath, and copper wire braid shielding |
|
KVVP2-22 |
Control cable with copper core, PVC insulation, PVC sheath, copper tape shielding, steel tape armor. |
2.XLPE insulation PVC sheath control cable
|
KYJV |
Control cable with copper core, cross-linked polyethylene insulation, and PVC sheath. |
|
KYJVR |
Control soft cable with copper core, cross-linked polyethylene insulation, PVC sheath |
|
KYJVP |
Control cable with copper core, cross-linked polyethylene insulation, copper wire braid shielding, PVC sheath. |
|
KYJVRP |
Control soft cable with copper core, cross-linked polyethylene insulation, copper wire braid shielding, PVC sheath. |
|
KYJVP2 |
Control cable with copper core, cross-linked polyethylene insulation, copper tape shielding, PVC sheath. |
|
KYJVRP2 |
Control soft cable with copper core, cross-linked polyethylene insulation, copper tape shielding, PVC sheath |
|
KYJV22 |
Control cable with copper core, cross-linked polyethylene insulation, PVC sheath, steel tape armor. |
|
KYJVP22 |
Control cable with copper core, cross-linked polyethylene insulation, copper braid shielding, PVC sheath, steel tape armor. |
|
KYJVP2-22 |
Control cable with copper core, cross-linked polyethylene insulation, copper tape shielding, PVC sheath, steel tape armor. |
3. Low-smoke, halogen-free, flame retardant polyolefin insulation and sheathing control cables
|
KYDYD |
Copper coreLow-smoke, halogen-free, flame retardant polyolefin insulated and jacketed control cable |
|
KYDYDR |
Copper coreLow-smoke, halogen-free, flame retardant polyolefin insulated and jacketed control flexible cable |
|
KYDYDP |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulated and jacketed copper wire braided screened control cable |
|
KYDYDRP |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulated and jacketed copper wire braided screened control flexible cable |
|
KYDYDP2 |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulated and jacketed copper tape shielded control cable |
|
KYDYD RP2 |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulated and jacketed copper tape shielded control flexible cable |
|
KYDYD-22 |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulated and jacketed steel tape armored control cable |
|
KYDYDP22 |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulated and jacketed copper wire braided shielding steel tape armor control cable |
|
KYDYDP2-22 |
Copper coreLow-smoke, halogen-free, flame retardant, polyolefin insulation and sheath, copper tape shielding, steel tape armor control cable |
|
Notes: Insulation and sheathing in the basic model are alsoYDJLow-smoke, halogen-free, flame retardant, cross-linked polyolefin |
|
Note: For flame retardant sheathed types, ZR should be added before the model, and tin-plated copper wires can be used in the conductor core.
Five: Code Name and Its Meaning
Table 2
|
Project |
Code name |
Explanation |
|
Flame retardant properties |
ZR |
GradeA, B, C flame retardant |
|
Series Designation |
K |
Control cable |
|
Insulation material |
V |
PVC; flame retardant PVC |
|
Y |
Polyethylene |
|
|
YD |
Low-smoke halogen-free polyolefins(YDJ low-smoke halogen-free cross-linked polyolefins) |
|
|
YJ |
Cross-linked polyethylene |
|
|
Sheath material |
V |
PVC; flame retardant PVC |
|
YD |
Low-smoke, halogen-free polyolefin |
|
|
Shielding material |
P |
Copper wire braided shielding |
|
P1 |
Tinned copper wire shielding |
|
|
P2 |
Copper tape shielding; |
|
|
P3 |
Aluminum plastic shrink shielding |
|
|
Armored material |
22 |
Steel tape armoured polyvinyl chloride sheath |
|
23 |
Steel tape armoured polyethylene sheath |
|
|
32 |
Steel wire armoured polyvinyl chloride sheath |
|
|
33 |
Steel wire armor polyethylene sheath |
|
|
Conductive structure |
A |
Single-strand conductor |
|
B |
7-strand twisted conductor |
|
|
R |
Multi-strand conductor |
Six: Main Technical Indicators
1. The direct current resistance of the finished cable conductor (Ω/km.20℃) shall be in accordance with the provisions of Table 3 in Appendix A.
2. Insulation resistance and insulation nominal thickness shall conform to the provisions of the following table:
|
Nominal cross section(mm2) |
Insulation nominal thickness(mm) |
Insulation resistance(MΩ/KM) |
|
|
20℃ |
70℃ |
||
|
0.5 |
0.6 |
13 |
0.013 |
|
0.75 |
0.6 |
12 |
0.12 |
|
1.0 |
0.6 |
11 |
0.011 |
|
1.5 |
0.7 |
11 |
0.011 |
|
2.5 |
0.8 |
10 |
0.010 |
|
4 |
0.8 |
8.5 |
0.0085 |
|
6 |
0.8 |
7 |
0.0070 |
|
10 |
1.0 |
6.5 |
0.0065 |
3. The finished cable shall withstand a 3.0 KV/5 min. alternating voltage test without breakdown.