Silicone rubber high temperature resistant control cable
Silicone rubber high temperature resistant control cable
Description
1. Product features and uses
This product is suitable for AC rated voltage 450/750V and below for the connection of electrical instruments or signal transmission for mobile or fixed laying of electrical appliances.
The cable has good thermal stability, can maintain good electrical performance and flexibility in high and low temperatures and corrosive environments, suitable
Metallurgy, electricity, petrochemical and other industries with special requirements for mobile temperature resistance.
Two: Product Implementation Standard
Q/HHTZH004.2
Flame retardant and fire resistance characteristics test is performed according to GB12666-90 standard
Three: Using Properties
1. AC rated voltage: U0/U 450/750KV
Maximum operating temperature: 180℃
2. Minimum ambient temperature: Silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃
3. The temperature for cable installation and laying should not be lower than -20℃.
4. Allowable bending radius of cables: For non-armored cables, the minimum is 6 times the outer diameter of the cable.
Four: Basic Model and Name
|
KGG |
Silicone rubber insulated and sheathed control cable |
|
KGGR |
Silicone rubber insulated and sheathed control flexible cable |
|
KGGP |
Silicone rubber insulated and sheathed copper wire braided shielded control cable |
|
KGGRP |
Silicone rubber insulated and sheathed copper wire braided shielded control flexible cable |
|
KGGRP1 |
Silicone rubber insulated and sheathed tin-woven shielding control flexible cable |
Note: 1. For flame retardant silicone rubber cable, add ZR before the model;
2 Silicone rubber insulated nitrile sheathed cable to replace silicone rubber insulated and sheathed heat-resistant control cable in the case of a large number of cores and large section.
The application is similar to that of silicone rubber sheathed cable, with a long-term use temperature of -60 to 105℃.
3-conductor wire cores can use tin-plated copper wire.
Five: Code Name and Its Meaning
Table 2
|
Project |
Code name |
Explanation |
|
Flame retardant properties |
ZR |
Flame retardant silicone rubber sheath |
|
Series Designation |
K |
Control cable |
|
Insulation material |
G |
Silicone rubber |
|
Sheath material |
G |
Silicone rubber |
|
YVF |
Nitrile PVC |
|
|
Shielding material |
P |
Copper wire braided shielding |
|
P1 |
Tin-plated copper wire shielding |
|
|
Conductive structure |
A |
Single-strand conductor |
|
B |
7-strand twisted conductor |
|
|
R |
Multi-strand conductor |
Six: Main Technical Indicators
1. DC resistance of the conductor of finished cable (in accordance with the provisions of GB3956) shall be in accordance with the provisions of Table 3 in Appendix A.
Insulation resistance shall not be less than 500MΩ/KM at 2.200℃.
3. The finished cable shall withstand a 3.0 KV/5 min alternating voltage test without breakdown.