Product Category:
Key word:
Nitrile-insulated and sheathed control flexible cables
Nitrile-insulated and sheathed control flexible cables
Description
1. Product features and uses
This product is suitable for the connection lines or signal transmission of electrical appliances and instruments for mobile use with a rated voltage of AC 450/750V and below. The cable has the characteristics of cold resistance, oil resistance, tensile strength, tear resistance, flexibility, etc., and is suitable for occasions with special requirements such as metallurgy, electricity, machinery, ports, etc.
Two: Product Implementation Standard
Q/HHTZH007.2
Flame retardancy tests are conducted according to GB12666-90 standards
Three: Using Properties
1. AC rated voltage: U0/U 450/750KV
Maximum operating temperature: 70℃(flame retardant type is 105℃)
2. Minimum ambient temperature: fixed laying -40℃, non-fixed laying -15℃
3. The temperature for cable installation and laying should not be lower than -20℃.
Four: Basic Model and Name
|
(K)YVFR |
Nitrile insulation and sheath control flexible cable |
|
(K)YVFRP |
Nitrile insulated and jacketed copper braided shielded control flexible cable |
Note: 1. For flame retardant cable, please add ZR in front of the model.
2Conductor wire core can use tin-plated copper wire.
3 Cables with special requirements can be produced according to the provided drawings or designed and produced according to the requirements of the operating environment.
Five: Code Name and Its Meaning
Table 2
|
Project |
Code name |
Explanation |
|
Flame retardant properties |
ZR |
Flame retardant nitrile soft cable |
|
Series Designation |
K |
Control cable |
|
Insulation sheath material |
YVF |
Nitrile |
|
Shielding material |
P |
Copper wire braided shielding |
|
P1 |
Tinned copper wire shielding |
|
|
Conductive structure |
A |
Single-strand conductor |
|
B |
7-strand twisted conductor |
|
|
R |
Multi-strand conductor |
Six: Main Technical Indicators
1. DC resistance of the conductor of the finished cable (in accordance with GB3956) referred to Table 3 in Appendix A.
Insulation resistance shall not be less than 50MΩ/KM at 2.20℃
2. The finished cable shall withstand a 3.0 KV/5 min voltage test at 50 Hz without puncture.
Relevant Qualifications
GB/T 19001-2016 /ISO 9001:2015
Quality Management System Certification Certificate
GBT 24001-2016 / ISO 14001:2015
GB/T 45001-2020/ ISO 45001:2018
Inquiry
*Note: Please be sure to fill in the information accurately and keep the communication open, we will contact you as soon as possible